Fluke 117 Compact True-RMS Electrician's Digital Multimeter with Non-Contact Voltage

SKU: 133029
Brand: Fluke Model: 117 Condition: New

Fluke 117 Digital Multimeter

Our Price: $179.95
Available to Ship: Within 24 Hours

Click to view pallet pricing

Add 12 more to get 5% off! ($170.95 each)

Ask a Question
About this Product

Purchase 1 piece, and earn 22 Westside Dollars

View All Fluke Electrical Test Equipment

Description

The Fluke 117 Digital Multimeter is a compact true-RMS electrician's meter is for use in commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The included integrated non-contact voltage detection help get the job done faster. Featuring AutoVolt automatic ac/dc voltage selection, low input impedance: helps prevent false readings due to ghost voltage and a large white LED backlight to work in poorly lit areas.

Fluke Meter includes: 4 mm silicone test lead set, Holster, User manual.

 

Features

• VoltAlert technology for non-contact voltage detection
• AutoVolt automatic ac/dc voltage selection
• Low input impedance: helps prevent false readings due to ghost voltage
• Large white LED backlight to work in poorly lit areas
• True-rms for accurate measurements on non-linear loads
• Measures 10 A (20 A overload for 30-seconds)
• Resistance, continuity, frequency and capacitance
• Min/Max/Average with elapsed time to record signal fluctuations
• Compact ergonomic design for one-handed operation
• Compatible with optional magnetic hanger (ToolPak) for hands free operation
• CAT III 600 V safety rated
• Electrician’s Multimeter with Non-Contact Voltage Includes: 4 mm silicone test lead set, Holster, and User manual

Specifications

• Model Number: 117
• Item Number: 2538815
• Maximum voltage between any terminal and earth ground: 600 V
• Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
• Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
• Display (Digital): 6,000 counts, updates 4 per second
• Bar graph: 33 segments, updates 32 per second
• Operating Temperature: -10 °C to + 50 °C
• Storage Temperature: -40 °C to + 60 °C
• Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
• Battery Life: 400 hours typical, without backlight
• DC millivolts Range: 600.0 mV
• DC millivolts Resolution: 0.1 mV
• DC millivolts Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
• DC volts Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
• DC volts Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
• Auto volts Range: 600.0 V
• Auto volts Resolution: 0.1 V
• Auto volts Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz), 4.0 % + 3 (500 Hz to 1 kHz)
• AC millivolts¹ true-rms Range: 600.0 mV
• AC millivolts¹ true-rms Resolution: 0.1 mV
• AC millivolts¹ true-rms Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz), 2.0 % + 3 (500 Hz to 1 kHz)
• AC volts¹ true-rms Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
• AC volts¹ true-rms Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz), 2.0 % + 3 (500 Hz to 1 kHz)
• Continuity Range: 600 Ω
• Continuity Resolution: 1 Ω
• Continuity Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer
• Ohms Range/Resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
• Ohms Accuracy: 0.9 % + 1
• Ohms Range/Resolution: 40.00 MΩ / 0.01 MΩ
• Ohms Accuracy: 5 % + 2
• Diode Test Range/Resolution: 2.000 V / 0.001 V
• Diode Test Accuracy: 0.9% + 2
• Capacitance Range/Resolution: 1000 nF / 1 nF, 10.00 µF / 0.01 µF, 100.0 µF / 0.1 µF, 9999 µF / 1 µF, 100 µF to 1000 µF
• Capacitance Accuracy: 1.9% + 2
• Capacitance Range/Resolution: > 1000 µF
• Capacitance Accuracy: 5% + 20%
• LoZ capacitance Range: 1 nF to 500 µF
• LoZ capacitance Accuracy: 10% + 2 typical
• AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A,
• AC amps true-rms (45 Hz to 500 Hz) Accuracy: 1.5% + 3, 20 A continuous overload for 30 seconds max
• DC amps Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
• DC amps Accuracy: 1.0% + 3, 20 A continuous overload for 30 seconds max
• Hz (V or A input)² Range/Resolution: 99.99 Hz / 0.01 Hz, 999.99 Hz / 0.1 Hz, 9.999 Hz / 0.001 Hz, 50.00 Hz / 0.01 Hz
• Hz (V or A input)² Accuracy: 0.1% + 2
• Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 inches)
• Weight: 550 g
• Warranty: 3 years

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

Customer Reviews

There are no reviews for this product yet. Be the first to review the product!

Write Your Own Review:

 1 star2 stars3 stars4 stars5 stars
Price
Value
Quality



Submit Review

Questions & Answers

Please login or register before adding a question.

If you are a new customer, please register first: