The Fluke 117 Digital Multimeter is a compact true-RMS electrician's meter is for use in commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The included integrated non-contact voltage detection help get the job done faster. Featuring AutoVolt automatic ac/dc voltage selection, low input impedance: helps prevent false readings due to ghost voltage and a large white LED backlight to work in poorly lit areas. Fluke Meter includes: 4 mm silicone test lead set, Holster, User manual.

Features
  • VoltAlert technology for non-contact voltage detection
  • AutoVolt automatic ac/dc voltage selection
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • True-rms for accurate measurements on non-linear loads
  • Measures 10 A (20 A overload for 30-seconds)
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak) for hands free operation
  • CAT III 600 V safety rated
  • Electrician’s Multimeter with Non-Contact Voltage Includes: 4 mm silicone test lead set, Holster, and User manual
Specifications
  • Model Number: 117
  • Item Number: 2538815
  • Maximum voltage between any terminal and earth ground: 600 V
  • Surge protection: 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
  • Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
  • Display (Digital): 6,000 counts, updates 4 per second
  • Bar graph: 33 segments, updates 32 per second
  • Operating Temperature: -10 °C to + 50 °C
  • Storage Temperature: -40 °C to + 60 °C
  • Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
  • Battery Life: 400 hours typical, without backlight
  • DC millivolts Range: 600.0 mV
  • DC millivolts Resolution: 0.1 mV
  • DC millivolts Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
  • DC volts Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
  • DC volts Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
  • Auto volts Range: 600.0 V
  • Auto volts Resolution: 0.1 V
  • Auto volts Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz), 4.0 % + 3 (500 Hz to 1 kHz)
  • AC millivolts¹ true-rms Range: 600.0 mV
  • AC millivolts¹ true-rms Resolution: 0.1 mV
  • AC millivolts¹ true-rms Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz), 2.0 % + 3 (500 Hz to 1 kHz)
  • AC volts¹ true-rms Range/Resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V
  • AC volts¹ true-rms Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz), 2.0 % + 3 (500 Hz to 1 kHz)
  • Continuity Range: 600 Ω
  • Continuity Resolution: 1 Ω
  • Continuity Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer
  • Ohms Range/Resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
  • Ohms Accuracy: 0.9 % + 1
  • Ohms Range/Resolution: 40.00 MΩ / 0.01 MΩ
  • Ohms Accuracy: 5 % + 2
  • Diode Test Range/Resolution: 2.000 V / 0.001 V
  • Diode Test Accuracy: 0.9% + 2
  • Capacitance Range/Resolution: 1000 nF / 1 nF, 10.00 µF / 0.01 µF, 100.0 µF / 0.1 µF, 9999 µF / 1 µF, 100 µF to 1000 µF
  • Capacitance Accuracy: 1.9% + 2
  • Capacitance Range/Resolution: > 1000 µF
  • Capacitance Accuracy: 5% + 20%
  • LoZ capacitance Range: 1 nF to 500 µF
  • LoZ capacitance Accuracy: 10% + 2 typical
  • AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A,
  • AC amps true-rms (45 Hz to 500 Hz) Accuracy: 1.5% + 3, 20 A continuous overload for 30 seconds max
  • DC amps Range/Resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A
  • DC amps Accuracy: 1.0% + 3, 20 A continuous overload for 30 seconds max
  • Hz (V or A input)² Range/Resolution: 99.99 Hz / 0.01 Hz, 999.99 Hz / 0.1 Hz, 9.999 Hz / 0.001 Hz, 50.00 Hz / 0.01 Hz
  • Hz (V or A input)² Accuracy: 0.1% + 2
  • Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 inches)
  • Weight: 550 g
  • Warranty: 3 yearsNotes:1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Customer Reviews
There are no reviews for this product yet. Be the first to review the product!

Write Your Own Review:

 1 star2 stars3 stars4 stars5 stars
Price
Value
Quality



Submit Review
Questions & Answers
Please login or register before adding a question.

If you are a new customer, please register first:

Feedback